  Datasheet File OCR Text:
 General Purpose Relays
Power Relay RM C/D
I I I I I I
1 pole 30 A, 1 NO or 1 NO + 1 NC contact Switching capacity up to 7500 VA DC- or AC-coil Push-to-test-button Chassis mount RoHS compliant (Directive 2002/95/EC) as per product date code 0415
Applications Battery chargers, heating control
F0166-A
Approvals
Z data of approved types on request E214025 Technical
Contact data RMC RMD
Contact configuration 1 NO and 1 NC 1 NO Contact set single bridging contact Type of interruption micro disconnection Rated current 30 A Rated voltage / max.switching voltage AC 400/440 VAC Maximum breaking capacity AC 7500 VA Limiting making capacity, max 20 ms 60 A Contact material AgCdO Mechanical endurance 10x106 cycles Rated frequency of operation with / without load 16/100 min-1 Contact Type RMC/D RMC/D ratings Load 30 A, 415 VAC, UL 30 A, 250 VAC, general purpose, UL
Cycles 10x103 6x103
Coil data
Rated coil voltage range DC coil AC coil Coil power DC coil AC coil Operative range 6...220 VDC 6...400 VAC 1.2 W 2.8 VA 1
Coil versions, DC-coil Coil code Rated Operate Release Coil Rated coil STD LED PD* LED+ voltage voltage voltage resistance power bipolar PD* VDC VDC VDC Ohm W 006 L06 0A6 LA6 6 4.5 0.6 32+10% 1.1 012 L12 0B2 LB2 12 9.0 1.2 110+10% 1.3 + 024 L24 0C4 LC4 24 18.0 2.4 475+10% 1.2 048 L48 0E8 LE8 48 36.0 4.8 2000+10% 1.2 060 L60 0G0 LG0 60 45.0 6.0 2850+10% 1.3 110 M10 1B0 MB0 110 82.5 11.0 10000+12% 1.2 221 N21 2C1 NC1 220 165.0 22.0 40000+15% 1.2 All figures are given for coil without preenergization, at ambient temperature +23C *) Protection diode PD; standard polarity: +A1 / -A2
1
Datasheet Rev. FK1 Issued 2006/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the `Schrack' section. Specifications subject to change.
General Purpose Relays
Power Relay RM C/D (Continued)
Coil versions, AC-coil 50/60 Hz Coil code Rated STD LED voltage
Terminal assignment
Bottom view on pins
Operate Release Coil Rated coil voltage voltage resistance power 50/60Hz 50/60Hz 50/60Hz VAC VAC VAC Ohm VA + 524 R24 24 19.2 9.6 80+10% 2.62/2.00 548 R48 48 38.4 19.2 320+10% 2.60/2.17 560 R60 60 48.0 24.0 500+10% 2.62/2.20 615 S15 115 92.0 46.0 1850+10% 2.65/2.22 + 730 T30 230 184.0 92.0 7500+10% 2.69/2.26 900 V00 400 320.0 160.0 23500+15% 2.61/2.20 All figures are given for coil without preenergization, at ambient temperature +23C
Insulation
Dielectric strength coil-contact circuit open contact circuit Clearance / creepage coil-contact circuit Material group of insulation parts Insulation to IEC 60664-1 Type of insulation coil-contact circuit open contact circuit Rated insulation voltage Pollution degree Rated voltage system Overvoltage category 2500 Vrms 1500 Vrms W 4/14.9 mm W IIIa 1 NO and 1 NC contact, RMC basic functional 250 V 3 240/400 V III
S0269-AK
Other data
RoHS - Directive 2002/95/EC compliant as per product date code 0415 Ambient temperature range DC coil -45...+60C AC coil -45...+40C Operate- / release time 17/18 ms Bounce time NO / NC contact 4 Vibration resistance (function) NO / NC contact 10/5 g, 30...150 Hz Category of protection RTI - dust protected Relay weight 81 g Packaging unit 10 pcs
S0269-AH
1 NO contact, RMD
S0269-AI
2
Datasheet Rev. FK1 Issued 2006/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the `Schrack' section. Specifications subject to change.
General Purpose Relays
Power Relay RM C/D (Continued)
Dimensions
Cover with mounting brackets, 6.3 mm quick connect terminals
S0298-BK
Product key Type Contact configuration C 1 NO contact and 1 NC contact, 30 A D 1 NO contact, 30 A Version 0 AgCdO, without test button 3 AgCdO, with test button Enclosure 5 cover with mounting brackets, 6.3 mm quick connect terminals Coil Coil code: please refer to coil versions table, preferred types in bold print
RM
5
Product key RMC05024 RMC05524 RMC05615 RMC05730 RMC35024 RMD05024 RMD05524 RMD05615 RMD05730 RMD35024 RMD35730
Contacts 1 NO + 1 NC contact 30 A 1 NO contact 30 A
Version without test button with test button without test button with test button
Enclosure mounting brackets quick c. 6.3 mm
Coil DC-coil AC-coil DC-coil AC-coil DC-coil AC-coil
Coil 24 VDC 24 VAC 115 VAC 230 VAC 24 VDC 24 VDC 24 VAC 115 VAC 230 VAC 24 VDC 230 VAC
Part number 4-1393844-5 0-1393146-5 8-1393147-7 0-1393146-6 0-1393146-7 0-1393146-9 1-1393146-1 0-1415009-1 4-1393844-7 2-1419136-2 0-1393097-5
3
Datasheet Rev. FK1 Issued 2006/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the `Schrack' section. Specifications subject to change.


▲Up To Search▲   

 
Price & Availability of RMC35024

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X